PC-MTS-01


This single system covers all aspects of motor torque measurement, such as speed-torque, cogging torque, and torque ripple. Combined with a power meter, it can be used to measure induced voltage. May be used in combination with environmental testing equipment.


| Load torque control range | 0.06 N·m – 2 N·m |
|---|---|
| Load torque detection accuracy | ±0.5% of range (full scale) |
| Allowable RPM | up to 20,000 r/min |
| RPM measurement accuracy | ±0.2% of range (full scale) |
| Maximum allowable power input | 600 W for five minutes |
| Torque detection range | When measuring torque ripple: -2 N·m – 2 N·m When measuring cogging torque: -50 mN·m – 50 mN·m |
|---|---|
| Torque detection accuracy | When measuring torque ripple: ±0.5% of range (full scale) When measuring cogging torque: ±1.5% of range (full scale) |
| Operating RPM | 1 – 20 r/min |
| Operating direction of rotation | CW/CCW |
| Operating angular measurement resolution | approximately 0.088°(2 r/min or less) approximately 0.35°(3 r/min or more) |
| Work operating RPM | 500 – 2,000 r/min |
|---|---|
| Work torque | 200 mN·m or less |
| Voltage measurement | particulars subject to separate consultation |
| Compatible personal computers | OS: Microsoft Window XP/7 |